Wind Tunnel - Technical Description

The wind tunnel in the lab at Multi-Wing Poland is designed in accordance with the principle outlined in AMCA 210-99 Figure12. The test chamber is an outlet type designed to handle ducted and none ducted fans. The 4 set-up types are as follows:

A: free inlet, free outlet 
B: free inlet, ducted outlet 
C: ducted inlet, free outlet 
D: ducted inlet, ducted outlet 


Multi-Wing International's database is generated using set-up A, following in general, the AMCA test method chapter 1-10